Function
restart - Restarts the Maestro and:
Closes all existing objects
Kills all virtual machines
Restarts the Maestro kernel
Applies the sessions and objects according to the existing
configuration file.
Call Format
restart
Limitations
Terminal only
Function
restarta - Restarts the Maestro and:
Closes all existing objects
Kills all virtual machines
Restarts the Maestro kernel
Applies the sessions and objects according to the existing
configuration file.
Starts the AUTOEXEC program (if it exists).
Call Format
restarta
Limitations
Terminal only
Function
restartd
- restarts the Maestro kernel with the default
configuration
and sets the baud rate for each CAN bus.
Call Format
restartd() – for baud rate 500 (default setting)
restartd(baudrate1, baudrate2) –baud rate 0 is not used. If the default
baud rate is not selected, a separate baud rate for each CAN bus must
be specified. If a baud rate for one bus is omitted, an error message is
displayed.
Limitations
Terminal only
Example
restartd(1000, 1000)
Function
restarte
- restarts the Maestro kernel without running the CAN
bus
.
Call Format
restarte()
Limitations
Terminal only
Maestro Software Manual General and Motion Instructions