Elmomc CANopen DSP 402 Implementation Guide Manuel d'utilisateur Page 24

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 116
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 23
Object 0x6505: http drive catalog address
This object gives the Internet address of the drive manufacturer.
Object description:
Index 6505h
Name http drive catalog address
Object code VAR
Data type VISIBLE_STRING
Category Optional
Entry description:
Access Read only
PDO mapping No
Value range
Default value http:\\www.elmomc.com
According to DSP 402, object 0x6505 has read/write access, although with the
SimplIQ, it has read only access.
Object 0x60FD: Digital inputs
This object defines simple digital inputs for drives.
The reflected functions are:
Negative limit switch – Similar to RLS
Positive limit switch – Similar to FLS
Home switch – As reflected in the IL[5] command
Object description:
Index 60FDh
Name Digital inputs
Object code VAR
Data type UNSIGNED32
Category Optional
Entry description:
Access Read only
PDO mapping Yes
Value range UNSIGNED32
Default value 0
CANopen DSP 402 Implementation Guide
MAN-CAN402IG (Ver. 1.2)
18
Vue de la page 23