Entry description:
Access Read/write
PDO mapping No
Value range UNSIGNED16
Default value No
Note: In the situation where the torque command value is not set to '0', a default
threshold of 25%is used.
Object 0x2F70 – CAN Encoder Range
Th
is object defines the range of the CAN Encoder. The low limit is stored in sub-index 1
and the high limit in sub-index 2.
Note: The difference of the limits must be a even numbers.
Object description:
Index 2F70h
Name Can Encoder Range
Object code ARRAY
Data type UNSIGNED32
Category Optional
Entry description:
Sub-index 0
Description Number of entries
Entry category Mandatory
Access Read only
PDO mapping No
Value range 2
Default value 2