MC - Maximum Peak Driver Current
Purpose:
Reports the maximum phase current allowed for the drive, in amperes. This command
informs the software about the type of servo drive used with the controller.
Attributes: Type: Report, Real
Source: Program, RS-232, CANopen
Restrictions: Read only
Unit modes: All
You may limit the current for a specific application using the PL[1] and CL[1]
commands.
See also:
IQ, ID, CL[N], PL[N]
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-87