LC - Current Limit Flag
Purpose:
Reports the status of the current limiting process. You may select two different current
limit specifications: The peak limit PL[1] specifies how much current can be applied to
the motor for short time periods (PL[2]) and the continuous limit CL[1] specifies how
much current can be applied to the motor continuously.
LC returns values according to the following table:
Value Description
0 The motor current is limited to the limit PL[1], or the motor is off.
1 The motor current is limited to the continuous limit CL[1].
Table 3-29: LC Return Values
Attributes: Type: Status report, Integer
Scope: Program, RS-232, CANopen
Restrictions: None
Unit modes: All
See also:
MC, PL[N], CL[N]
Reference chapter in The
SimplIQ Software Manual:
Chapter 10, ”The Current Controller”
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-82