Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: Advanced model only
Default values: EM[1]=0, EM[2]=2, EM[3]=0, EM[4]=1000,
EM[5]=1, EM[6]=1, EM[7]=0, EM[8]=0
(RS), Non-volatile
Range: EM[1]: [0…2]
EM[2]: [2…1024]
EM[3]: Position counter range
EM[4]: [1…32,000]
EM[5]: [1…1023]
EM[6]: [1…1024]
EM[7]: 1…32,000]
Index range: Write: [1…7]
Read: [1…8]
Unit modes: UM=3, 4, 5
Activation: See previous Notes
See also:
RM, FR[N]
Reference chapter in the SimplIQ Software Manual:
Chapter 12, ”The Position Reference Generator”
SimplIQ Command Reference Manual Alphabetical Listing